Technical Library &
Compliance Hub
Download ASTM/EN Certified Test Dossiers, BIM LOD 400 Families, CAD Detail Sections, and Facade Engineering Whitepapers for high-performance building envelopes.
Validated Engineering Artifacts
Rig Dynamic Wind Load & Air/Water Infiltration Dossier
Full-scale environmental chamber performance verification reaching 6.20 kPa dynamic structural pressure with zero moisture failure under pulsating water heads.
Fire Reaction Classification (Class A1 / A2-s1, d0)
Combustibility, heat release rate (FIGRA), smoke emission, and flaming droplet testing certificates for both solid core and honeycomb infill composites.
Solid Aluminum Cladding Detail Library (Expansion & Spandrels)
Standard 2D and 3D DWG blocks covering dead-load mullion anchors, hyperbolic curved perimeter spandrels, thermal break junctions, and silicone gaskets.
Intelligent Motorized Louver LOD 400 Parametric Family
Includes full fabrication geometry, actuator cable conduit paths, automated thermal solar tracking control logic, and COBie asset scheduling attributes.
Sound Transmission Loss & Acoustic Barrier Report
Independent laboratory acoustic transmission index (Rw / STC 38-44 dB) measuring honeycomb sandwich panels engineered with high-density mineral decoupling layers.
4,000-Hour Accelerated Salt Spray & Cyclic Corrosion Report
Marine and coastal harsh atmosphere exposure data. Zero blister initiation, under-film corrosion creep below 0.5mm on marine-grade 5052 and 3003 alloys.
Architectural Anodizing & PVDF Resin Coating Manual
Definitive master specification guidance covering 70% Kynar 500 / Hylar 5000 multi-coat liquid spray vs. class 1 hard-coat architectural anodization (25μm).
Seismic Interstory Drift & Dynamic Displacements
Full-scale cyclic horizontal displacement testing measuring envelope panels subjected to design displacement (0.010 H) and extreme drift limit states (0.015 H).
Preliminary Calculation Modules
Real-time structural estimation engines calibrated against Eurocode EN 1991-1-4 and ASCE 7-16 facade wind pressure matrices.
Calculate overall envelope Solar Heat Gain Coefficient (SHGC) with integrated dynamic louver angle modulation.
Check allowable unbraced mullion span according to ASCE 7-16 / EN 1991 wind pressure requirements.
Determine minimum plate gauge or honeycomb sandwich core thickness to avoid permanent deflection ($L/180$).
Environmental Product Declarations (EPD) & Green Building Credits
Accelerate LEED v4/v4.1, BREEAM, and DGNB credits with third-party verified Type III EPD dossiers, post-consumer recycled aluminum content statements (up to 75% recycled billet), and Life Cycle Assessments (ISO 14025 / EN 15804).
Green Building Package
Full Documentation Suite · 34 MBCustom Specification & Facade Engineering Support
Need tailored wind-tunnel pressure assessments, custom die-extrusion shop drawings, or project-specific mock-up witness test protocols? Transmit your project details to our technical team in Rotterdam or Foshan.
Project-Specific Engineering
Calculation books signed by certified structural façade engineers for local authority approval (IBC/Eurocodes).
24-48 Hour Turnaround
Rapid turnaround for preliminary submittals, CAD block custom adaptations, and panel schedules.